Skip to content
Popular Calculators
Browse Construction calculators

Roof Pitch Calculator

Convert a roof’s rise and run, or its angle, into pitch in 12, degrees, percent grade and pitch factor, with what the slope suits.

About the Roof Pitch Calculator

A roof's pitch is how steeply it rises. It decides which roofing materials can be used, how much the roof covering will cost, how easy the roof is to work on, and how much usable space there is in the loft. It is also stated in several different ways, which causes a lot of confusion.

Builders and roofers in North America give pitch as rise in 12 — "a 6/12 roof" rises 6 inches for every 12 inches it runs horizontally. Architects and most of the rest of the world use degrees. Engineers and some product literature use a percent grade or a ratio. They all describe the same right-angled triangle of rise and run.

This roof pitch calculator takes a measured rise and run, or an angle, and converts it to every other form, with the pitch factor used to estimate roof area and a note on what the slope is suitable for.

How to Use the Roof Pitch Calculator

Choose how you have measured the roof: rise and run, or angle in degrees.

For rise and run, enter the vertical rise and the horizontal run over which it was measured. Any unit works — inches, millimetres, feet — as long as both are in the same one, because only their ratio matters.

For angle, enter the angle from horizontal, for example from an inclinometer app.

How the Pitch Is Worked Out

  rise in 12    =  rise ÷ run × 12
  angle         =  atan(rise ÷ run)
  percent grade =  rise ÷ run × 100
  pitch factor  =  √(1 + (rise ÷ run)²)

Step-by-Step Example

A rise of 450 mm measured over a run of 1000 mm.

  Rise in 12:    450 ÷ 1000 × 12        =  5.4 in 12
  Angle:         atan(0.45)             =  24.2°
  Grade:         0.45 × 100             =  45%
  Pitch factor:  √(1 + 0.45²)           =  1.097

The closest common pitch is 5½ in 12. Working the other way, an angle of 30° is 6.93 in 12 — almost exactly a 7 in 12 roof.

Common Pitches

PitchAngleGradePitch factor
2 in 129.5°16.7%1.014
4 in 1218.4°33.3%1.054
6 in 1226.6°50.0%1.118
8 in 1233.7°66.7%1.202
10 in 1239.8°83.3%1.302
12 in 1245.0°100%1.414

What Each Slope Suits

Below 2 in 12 (about 9.5°) is a flat or low-slope roof. Water drains slowly, so overlapping materials such as shingles and tiles would leak. These roofs use continuous membranes: EPDM rubber, TPO, PVC or modified bitumen.

2 to 4 in 12 can take asphalt shingles, but manufacturers require a double layer of underlayment or a full ice-and-water membrane underneath.

4 to 9 in 12 is the conventional range. Shingles, concrete and clay tiles, slate and metal all work, and the roof can be walked on with care.

Above 9 in 12 (about 37°) is steep. It sheds water and snow quickly and looks dramatic, but roofers need roof jacks, toe boards or harnesses, and labour costs more per square. Many tile and slate systems have their own minimum pitches, so always check the manufacturer's figure.

Measuring Pitch Safely

You do not need to climb onto the roof.

From the loft: hold a spirit level horizontally with one end touching the underside of a rafter. Mark 12 inches (or 300 mm) along the level from the rafter, then measure straight up from that mark to the rafter. That height over 12 is the pitch.

From the gable end: hold a phone inclinometer app, or a digital angle finder, against the edge of the verge or a rafter tail.

From plans: architectural drawings usually state the pitch in degrees, and elevations can be scaled.

Pitch and Loft Space

A steeper roof encloses much more volume. On a 30 ft (9 m) wide house, a 4 in 12 roof rises only 5 ft (1.5 m) at the ridge, while a 12 in 12 roof rises 15 ft (4.5 m) — enough for a loft conversion. That is one reason older houses with steep roofs are popular for loft rooms.

Pitch, Slope and "Pitch" in the Old Sense

Understanding Your Result

Pitch gives the rise in 12 and the angle.

Grade and ratio gives the percent grade and the 1 : n ratio.

Pitch factor is the multiplier from plan area to roof area.

Slope type says what the roof is suited to.

Worth knowing gives the closest common pitch, or a note on rafter cuts.

When Should You Use This Calculator?

Before ordering roofing, to check the materials suit the slope.

Converting plans from degrees to rise in 12, or the reverse.

Designing an extension, to match an existing roof.

With the roofing calculator, which uses the pitch factor for area.

Common Mistakes

Confusing pitch and slope. Rise in 12 is not the same as degrees.

Measuring run along the slope. Run is horizontal.

Mixing units. Rise and run must be in the same unit.

Ignoring the minimum pitch for tiles, slate or shingles.

Guessing from the ground. Measure it.

Frequently Asked Questions

How do I work out roof pitch?

Measure the vertical rise over a known horizontal run, divide the rise by the run and multiply by 12. That gives the rise in inches for every foot of run. A roof that rises 6 inches over 12, or 450 millimetres over 900, is a 6 in 12 pitch.

What is a 6/12 roof pitch in degrees?

A 6 in 12 pitch is 26.6 degrees, found as the arctangent of 6 divided by 12. A 4 in 12 pitch is 18.4 degrees, 8 in 12 is 33.7 degrees and 12 in 12 is exactly 45 degrees. The same slope as a percent grade is 50 percent.

What is a pitch factor?

The pitch factor is how much longer the sloping roof is than the horizontal distance it covers, the square root of one plus the rise over run squared. Multiplying a building’s plan area by the pitch factor gives the roof area, which is how roofing materials are estimated.

How can I measure roof pitch without going on the roof?

In the loft, hold a spirit level level against the underside of a rafter, mark 12 inches along the level, and measure straight up from that mark to the rafter. That height is the rise in 12. Phone inclinometer apps held against a gable end or rafter give the angle directly.

What pitch is considered steep?

Roofers usually treat anything above about 9 in 12, roughly 37 degrees, as steep, needing roof jacks or harnesses to work on safely. Below 4 in 12 is low slope, where shingles need extra underlayment, and below 2 in 12 needs a membrane roof instead.

Last reviewed September 24, 2026 by the CalculatorPeak editorial team.